Apollo 10.0 KVA True Online UPS (1:1 Phase)

Apollo 10.0 KVA True Online UPS (1:1 Phase)

      SPECIAL FEATURES:

  • True on-line dual conversion design

  • Generator Compatible

  • All  Protections over/low-voltage, overcurrent, overload

  • Intelligent Battery Management, extended battery life

  • Intelligent Self diagnose function, all kinds of fault protection 

  • Modularized  design of subsystems

  • Bypass back feed protection, battery leakage protection

  • Parallel Redundancy design, increase the system reliability

  • Customizable wide input voltage range

  • Large size input LCD display on front panel




Apollo 10.0 KVA True Online UPS (1:1 Phase)

MODEL

2B10K / 2B10K-L

CAPACITY (VA Rating)

10.0 KVA

INPUT

Voltage

Single Phase, 110Vac~ 290Vac

Frequency

50 Hz (60 Hz on request) ± 5%

Power factor

> 0.98% (full load)

OUTPUT

Voltage

220Vac

Voltage Regulation

220Vac ± 0.5%

Transient Response

± 3~4% under full load, change and corrected within 2 ms

Wave form 

Pure Sinewave THD<3%

Power factor

0.8 

Frequency

50 / 60Hz, ± 0.5%

Crest Factor

3:1

Overload

Continuous alarming, switch to bypass, auto recovery upon removing of load

Overload Capacity

<110% load Continuous

110-125% load 12 Minutes

125-150% load 10 Minutes

>150% load: by pass

Battery

Battery Type

Maintenance free lead-acid batteries

DC Voltage

192VDC

Backup time

15-30 minutes depending on load

External Battery 

Up to 8 hours long time backup depends on external battery

Supplementary Charger

Optional 200W/500W charger for extended back-up application

Recharge time

5~8 hours

Cold Start

Yes, UPS cab be started without AC source

Battery Cabinet 

External Battery back 

TRANSFER TIME

Zero (0) millisecond, Inverter to Bypass (Overload)

PROTECTIONS

High Voltage, Overload, Overheating, bypass, Short circuit, Noise Filtering, Spike, Surge

EMI FILTER

10~100 KHz at 40dB, 100KHz~100MHz at 70Db

ALARM

Audio alarm

Keep 90 seconds at a time interval of 4 seconds

Battery Low

Auto shutdown upon complete discharge of battery and auto tum-on upon recovery of utility power 

Fault

Continuous alarming

INTERFACE

RS232 / SNMP

SOFTWARE MANGEMENT

AC fault, low battery, intelligent software for shutdown by remote control

TRONSFORMER TYPE

Built-in Galvanic Isolation Transformer

General

Dimensions (mm)

480x340x845

Weight (KG)

106

OPERATING ENVIRONMENT

Temperature

0 ~ 40°C (32 - 104°F)

Humidity

30 ~ 90% non-condensing

Attitude

<1500M above sea level

Audio nois